Safety switches - featuring the double door safety switch
9:18
In today’s world it’s a high priority to create a safer environment for everyone close to and working on electrical equipment. With this intention, safety switches have evolved to offer more robust protection for equipment and personnel. Safety switches are a common disconnecting means for service entrance and motors, while simultaneously providing motors with fault protection. Erik Hurd, Senior Power System Experience Center (PSEC) Engineer, explains types of safety switches and National Electrical Code (NEC) article 430.102B that necessitates them. Erik goes on to discuss Eaton’s compartmentalized fusible safety switch, the double door line isolation switch. This enhanced switch is a two-door design that places an emphasis on safety. Within the enclosure there is an internal barrier that separates the upper switching compartment from the lower fuse compartment. This allows operators to access the fuse compartment without any exposure to line-side power, providing enhanced safety during fuse replacement. Erik also demonstrates Eaton’s OEM line isolation switch which provides an external disconnecting means for industrial control panels. This panel also allows an operator to access the control panel without exposure to the line-side voltage. This results in enhanced safety and allows for reduced PPE, as well as improves worker dexterity and mobility. Learn more about Eaton’s full line of general-duty, heavy-duty, double-throw, hazardous area, and innovative new products for a vast variety of applications: https://www.eaton.com/us/en-us/products/low-voltage-power-distribution-control-systems/switches---disconnects.html For more info on Eaton’s Switching Device Flex Center, visit https://www.eaton.com/us/en-us/products/low-voltage-power-distribution-control-systems/switches---disconnects/switching-devices-flex-center.html Thank you for watching one of our many educational videos on the topic of power systems. Schedule a visit to one of Eaton's Power Systems Experience Centers in either Pittsburgh or Houston to learn more! To learn more about Eaton products and our Power Systems Experience Centers: http://eaton.com/experience To view more educational videos from Eaton's Power Systems Experience Centers: http://videos.eaton.com/experience 00:00 Intro 00:44 NEC article 430.102B 2:00 Types of safety switches 04:08 Double door line isolation switch 06:08 OEM line isolation (OLI) switch 07:43 Eaton Switching Device Flex Center #safetyswitch #electricalsafety #electricity
In today’s world it’s a high priority to create a safer environment for everyone close to and working on electrical equipment. With this intention, safety switches have evolved to offer more robust protection for equipment and personnel. Safety switches are a common disconnecting means for service entrance and motors, while simultaneously providing motors with fault protection. Erik Hurd, Senior Power System Experience Center (PSEC) Engineer, explains types of safety switches and National Electrical Code (NEC) article 430.102B that necessitates them. Erik goes on to discuss Eaton’s compartmentalized fusible safety switch, the double door line isolation switch. This enhanced switch is a two-door design that places an emphasis on safety. Within the enclosure there is an internal barrier that separates the upper switching compartment from the lower fuse compartment. This allows operators to access the fuse compartment without any exposure to line-side power, providing enhanced safety during fuse replacement. Erik also demonstrates Eaton’s OEM line isolation switch which provides an external disconnecting means for industrial control panels. This panel also allows an operator to access the control panel without exposure to the line-side voltage. This results in enhanced safety and allows for reduced PPE, as well as improves worker dexterity and mobility. Learn more about Eaton’s full line of general-duty, heavy-duty, double-throw, hazardous area, and innovative new products for a vast variety of applications: https://www.eaton.com/us/en-us/products/low-voltage-power-distribution-control-systems/switches---disconnects.html For more info on Eaton’s Switching Device Flex Center, visit https://www.eaton.com/us/en-us/products/low-voltage-power-distribution-control-systems/switches---disconnects/switching-devices-flex-center.html Thank you for watching one of our many educational videos on the topic of power systems. Schedule a visit to one of Eaton's Power Systems Experience Centers in either Pittsburgh or Houston to learn more! To learn more about Eaton products and our Power Systems Experience Centers: http://eaton.com/experience To view more educational videos from Eaton's Power Systems Experience Centers: http://videos.eaton.com/experience 00:00 Intro 00:44 NEC article 430.102B 2:00 Types of safety switches 04:08 Double door line isolation switch 06:08 OEM line isolation (OLI) switch 07:43 Eaton Switching Device Flex Center #safetyswitch #electricalsafety #electricity
Related videos for "motors eaton videos"
-
Locating motor ground faults with intelligent motor control on high-resistance grounded (HRG) systems
7:53
Application engineer Yzhi Alexander demonstrates the pulse detection feature in Eaton's Power Xpert C445 intelligent motor management relay. Within a high resistance grounding (HRG) system, the Power Xpert C445 can monitor and detect ground faults.
-
Motor control fundamentals | Eaton PSEC
10:30
Motor starters are electrical devices used to safely start/stop, reverse, and protect motors. In this video we explain how motor starters work, various design options, and applications in which they are used.
-
Motors 101
11:27
Engineer Santino Graziani discusses all the need-to-know basics of electric motors.