Ohmic voltage sensing (OVS) systems for medium-voltage switchgear
5:30
Discussion on how ohmic voltage sensing (OVS) systems in medium voltage switchgear can mitigate primary switching transients and ferroresonance thereby increasing reliability. Medium-voltage metal-clad switchgear uses protective relays for protection from abnormal conditions, essentially operating the breaker based on input readings. However, the relays need to be isolated from the high voltage of medium-voltage switchgear, which is the role that voltage transformers (VTs) play. VTs have a core and coil design which leaves the switchgear vulnerable to switching transients and ferroresonance issues. Switching transients are momentary changes in voltage, current or frequency. In power systems, switching transients are initiated by an abrupt change of circuit conditions (i.e., opening or closing of a breaker or contactor). In medium voltage, ferroresonance is a condition where the inductance of the magnetizing branch of the potential transformer (PT) and the distributed capacitance of the power system conductors excites a situation that causes the PT to falsely represent the actual voltage of the power system and may damage the PT or actuate the fuses on the system. This video also discusses how an OVS system operates, installation examples, and other benefits of OVS systems. Watch: Medium-voltage (MV) air insulated and gas insulated switchgear explained https://www.youtube.com/watch?v=nNWb5JEshAM Thank you for watching one of our many educational videos on the topic of power systems. Schedule a visit to one of Eaton's Power Systems Experience Centers in either Pittsburgh or Houston to learn more! To learn more about Eaton products and our Power Systems Experience Centers: http://eaton.com/experience To view more educational videos from Eaton's Power Systems Experience Centers: http://videos.eaton.com/experience 00:00 Intro 00:43 Measuring medium voltage switchgear 02:05 How OVS works 03:34 OVS in application 04:11 Benefits of OVS #OVS #ferroresonance #powersystem
Discussion on how ohmic voltage sensing (OVS) systems in medium voltage switchgear can mitigate primary switching transients and ferroresonance thereby increasing reliability. Medium-voltage metal-clad switchgear uses protective relays for protection from abnormal conditions, essentially operating the breaker based on input readings. However, the relays need to be isolated from the high voltage of medium-voltage switchgear, which is the role that voltage transformers (VTs) play. VTs have a core and coil design which leaves the switchgear vulnerable to switching transients and ferroresonance issues. Switching transients are momentary changes in voltage, current or frequency. In power systems, switching transients are initiated by an abrupt change of circuit conditions (i.e., opening or closing of a breaker or contactor). In medium voltage, ferroresonance is a condition where the inductance of the magnetizing branch of the potential transformer (PT) and the distributed capacitance of the power system conductors excites a situation that causes the PT to falsely represent the actual voltage of the power system and may damage the PT or actuate the fuses on the system. This video also discusses how an OVS system operates, installation examples, and other benefits of OVS systems. Watch: Medium-voltage (MV) air insulated and gas insulated switchgear explained https://www.youtube.com/watch?v=nNWb5JEshAM Thank you for watching one of our many educational videos on the topic of power systems. Schedule a visit to one of Eaton's Power Systems Experience Centers in either Pittsburgh or Houston to learn more! To learn more about Eaton products and our Power Systems Experience Centers: http://eaton.com/experience To view more educational videos from Eaton's Power Systems Experience Centers: http://videos.eaton.com/experience 00:00 Intro 00:43 Measuring medium voltage switchgear 02:05 How OVS works 03:34 OVS in application 04:11 Benefits of OVS #OVS #ferroresonance #powersystem
Electrical distribution Similar Videos
-
Eaton transformer testing facilities | Eaton PSEC
6:13
Eaton’s Power System Experience Center began as a transformer test lab. Today, Eaton has a leading transformer test lab and manufacturing facility in Juarez. Learn about harmonic effects as we discuss the Juarez test lab capabilities.
-
Circuit protection | Eaton PSEC
9:15
Circuit protection is a system of devices used to protect electrical circuits from electrical faults such as short circuits, overcurrent, and high temperature. Common circuit protection devices include circuit breakers, fuses, and protective relays.
-
Impedance in power systems explained | Eaton PSEC
8:55
Impedance is a measure of how much a circuit resists the flow of alternating current (AC). High impedance means less current, leading to inefficiencies and power losses. Learn where impedance comes from and how it affects electrical systems.